Powerful UPS with premium protection features for computers and electronic systems
- Warning tones notify the user when the status of the power supply or UPS system changes.
- Periodic, automatic battery self-tests for timely replacement of depleted batteries.
- Automatic Voltage Regulation (AVR) gradually increases low voltage and reduces high voltage to a level suitable for your devices.
- Analyses for early detection of battery faults enable timely preventive maintenance.
- Tool-free battery replacement for quick and easy battery changes.
- Battery-supported outputs and outputs with surge protection without battery support.
- Reserves capacity and bridging time for connected devices that need to switch to UPS battery operation in an emergency. This protects only less critical devices from surges.
Automatic Voltage Regulation (AVR) with boost and trim function to enhance UPS availability by correcting over- and under-voltage without using the battery.
Supports cold start for temporary battery operation when the mains supply fails.
Surge protection devices to protect connected devices from surges on data lines.
Notification of disconnected battery not available for power supply.
Patented Green Operating Mode, where unused electrical components are turned off under good power supply conditions, achieving very high operating efficiency without compromising safety.
Hot-swappable batteries for uninterrupted power supply to protect systems during a battery change.
LCD graphic display showing operating modes, system parameters, and alarms in the form of text and overview diagrams.
USB interface for managing the UPS via the USB port.
User-replaceable batteries for availability and reduced mean time to repair.
| Manufacturer | APC |
| Product Group | UPS |
| Product Type | UPS Line Interactive |
| Color | black |
| Scope of Delivery | UPS, software, cable set |
| Classification according to IEC 62040-3 | VFD-SY-333 |
| UPS Technology | Line Interactive |
| Power (VA/W) | 650 / 390 |
| Support Time at Full/Half Load | 2.7 / 10 min |
| Dimensions (HxWxD) | 190 x 91 x 310 mm |
| Form Factor | Tower |
| Voltage (Input) | 196 - 280 V |
| Voltage (Output) | 230V |
| Frequency | 50 Hz +- 3 % |
| Connection Type (Input) | C14 Cold Device |
| Connection Type (Output) | 6 C13 Cold Devices |
| Phases Input/Output | 230V/230V / 50Hz |
| Surge Protection | EMI, RFI Filter |
| Runtime Extension Unit | no |
| Slot for Adapter Card | no |
| Noise Level | 45 dB |
| Interfaces | USB |
| USB 2.0 Interface | yes |
| Hot Swap Batteries | no |
| Bypass | no |
| Operating Display | Display |
| Operating Display Screen | yes |
| including Management Software OS | Windows |
| Internal Cooling | passive |
| Ambient Temperature | 0-40°C |
| Operating Temperature Min. | 0 °C |
| Operating Temperature Max. | 40 °C |
| Height | 190 mm |
| Width | 91 mm |
| Depth | 310 mm |
| Weight | 6.4 kg |
| Packaging Height | 260 mm |
| Packaging Width | 140 mm |
| Packaging Depth | 440 mm |
| Package Weight | 7.323 kg |
| Gross Weight | 7.323 |